Titel:Rotierendes oder fixiertes Tibiainlay? Randomisierter klinischer und radiologischer Vergleich rotierender und fixierter Tibiainlays bei computerassistiertem bikondylärem Kniegelenkoberflächenersatz
Autor:Sufi-Siavach, Anusch
Weitere Beteiligte: Fuchs-Winkelmann, Susanne (Prof. Dr.)
Veröffentlicht:2010
URI:https://archiv.ub.uni-marburg.de/diss/z2010/0055
URN: urn:nbn:de:hebis:04-z2010-00557
DOI: https://doi.org/10.17192/z2010.0055
DDC:610 Medizin
Titel (trans.):Mobile- versus fixed-bearing. Comparison of rotating and fixed inlays in computer assisted total knee arthroplasty in a double-blind randomized controlled trial.
Publikationsdatum:2010-03-16
Lizenz:https://rightsstatements.org/vocab/InC-NC/1.0/

Dokument

Schlagwörter:
Fixed bearing, Mobile bearing, Bikondylärer Oberflächenersatz, Polyethyleninlay, Total knee replacement, Rotating platform, Fixiertes Gleitlager, Mobiles Gleitlager, Total knee arthroplasty, Rotierende Plattform, Kniegelenkprothese

Zusammenfassung:
Hintergrund: Mobilen Tibiainlays in der Knieendoprothetik werden theoretische Eigenschaften bescheinigt, die zu verbesserten funktionellen Ergebnissen und auf längere Sicht zu reduziertem Polyethylenabrieb führen sollen. Diese Studie untersuchte kurzfristige klinische Resultate von zwei Patientengruppen, die sich systematisch lediglich in der Art der verwendeten Tibiaplattform unterschieden. Eine Gruppe erhielt ein fixiertes Inlay, während der anderen ein mobiles implantiert wurde. Methoden: 100 Kniegelenke bei 97 Patienten wurden gemäß ihres Alters sowie nach ihrem Geschlecht stratifiziert und in zwei Gruppen randomisiert: fixed-bearing (FB) mit 52 Kniegelenken und rotating platform (RP) mit 48 Kniegelenken. Alle Patienten erhielten den das hintere Kreuzband erhaltenden bikondylären Oberflächenersatz Columbus® (B. Braun Aesculap, Tuttlingen, Germany) mit entweder festem oder rotierendem Polyethylen-Inlay. Die Prozeduren wurden von zwei erfahrenen Operateuren durchgeführt, und die Gruppen folgten einem identischen Rehabilitationsschema. Klinische Nachuntersuchungen fanden in doppelt verblindeter Art vor der Operation sowie drei, sechs und zwölf Monate danach statt. Zur klinischen Bewertung wurden der wissenschaftlich etablierte Knee Society Score (KSS) und der Oxford Knee Score (OKS) verwendet. Bei der statistischen Auswertung kamen der Mann-Whitney-U-Test mit alpha = 0,05 und beta = 0,15 für den primären Endpunkt eines als klinisch relevant angenommen KSS-Unterschiedes von mehr als acht Punkten zur Anwendung sowie Varianzanalysen (ANOVA) für das explorative Testen des Einflusses der Ausgangswerte der Scores als Kovariaten und der Nachuntersuchungszeitpunkte auf die Resultate. Ergebnisse: Der primäre Endpunkt des KSS sowie die sekundären Endpunkte des OKS und der range of motion (ROM) waren zwischen den Gruppen nicht statisch signifikant unterschiedlich. Sowohl die demographischen Daten der Untersuchungsgruppen als auch deren radiologisches Alignment prä- und postoperativ zeigten sich homogen. Wurden bei der statistischen Analyse die präoperativen Ausgangswerte der Scores als Kovariaten mit einbezogen und deren Einfluss untersucht, so ließen sich ebenfalls keine signifikanten Differenzen zwischen den Gruppen nachweisen. Schlussfolgerung: In unserer Untersuchung zeigte sich kein Unterschied im KSS von mehr als acht Punkten im ersten Jahr nach der Operation zwischen der FB- und der RP-Gruppe beim bikondylären Kniegelenkoberflächenersatz. Das Studiendesign kontrollierte darüber hinaus auf diverse andere Differenzen zwischen den Gruppen sowie den Einfluss zusätzlicher Variablen neben der Art des Tibiainlays auf die Ergebnisse. Auch dabei ließen sich keine signifikanten Unterschiede nachweisen. Hinsichtlich des ersten postoperativen Jahres und für Patienten, die unsere Einschlusskriterien erfüllten, konnte dementsprechend kein Vorteil für weder die fixierte noch die mobile Tibiaplattform herausgestellt werden. Es liegt nach den aktuellen wissenschaftlichen Erkenntnissen demnach kein schlüssiges Argument vor, eines der beiden Implantatdesigns zu bevorzugen.

Bibliographie / References

  1. Fixed-bearing versus mobile-bearing total knee arthroplasty: a prospective rando- mised, clinical and radiological study with mid-term results at 7 years. Knee, 15 (3): 206-210.
  2. Athletic activity after total joint replacement. Orthopedics, 25 (11): 1283-1287.
  3. The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J Biomed Mater Res, 58 (3): 282-290.
  4. Price, A.J., Rees, J.L., Beard, D., Juszczak, E., Carter, S., White, S., de Steiger, R., Dodd, C.A., Gibbons, M., McLardy-Smith, P., Goodfellow, J.W., Murray, D.W. (2003). A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br, 85 (1): 62-67.
  5. Motion of a mobile bearing knee allowing translation and rotation. J Arthroplasty, 17 (1): 11-19.
  6. Computer navigation versus conventional implantation for varus knee total arthro- plasty: a case-control study at 5 years follow-up. Knee, 15 (2): 75-79.
  7. 155 Solarino, G., Luca, A., Marzo, L., Scialpi, L., Solarino, G.B. (2008). Comparison among total knee arthroplasties with a mobile bearing: menisci versus rotating platform versus AP glide platform. Chir Organi Mov, 92 (2): 79-83.
  8. Comparison of the PFC Sigma fixed-bearing and rotating-platform total knee ar- throplasty in the same patient: short-term results. J Arthroplasty, 19 (1): 35-39.
  9. 47 Evaluation of image guiding surgery systems, E.o.i.g.s. (2002).
  10. Alignment in total knee replacement. J Bone Joint Surg Br, 90 (9): 1121-1127.
  11. 46 Ensini, A., Catani, F., Leardini, A., Romagnoli, M., Giannini, S. (2007). Alignments and clinical results in conventional and navigated total knee arthro- plasty. Clin Orthop Relat Res, 457: 156-162.
  12. An experimental model of tibial counterface polyethylene wear in mobile bearing knees: the influence of design and kinematics. Biomed Mater Eng, 9 (3): 189-196.
  13. An oxidized Zr ceramic surfaced femoral component for total knee arthroplasty. Clin Orthop Relat Res, (416): 191-196.
  14. Anterior knee pain with a posterior-stabilized mobile-bearing knee prosthesis: the effect of femoral component design. J Arthroplasty, 18 (4): 396-400.
  15. Atlas der Anatomie des Menschen. Stuttgart: Georg Thieme Verlag.
  16. Orthopädie (2. Auflage). Stuttgart: Hippokrates Verlag.
  17. Kniegelenk. In: D. Drenckhahn, W. Zenker (Hrsg.), Benninghoff -Anatomie, Band 1. (15. Auflage): 357-367. München, Wien, Baltimore: Urban & Schwarzenberg.
  18. 77 Ingham, E., Fisher, J. (2000). Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng [H], 214 (1): 21-37.
  19. Biological reaction to debris in relation to joint prostheses. Proc Inst Mech Eng [H], 211 (2): 187-197.
  20. 151 Sheth, N.P., Lementowski, P., Hunter, G., Garino, J.P. (2008). Clinical applications of oxidized zirconium. J Surg Orthop Adv, 17 (1): 17-26.
  21. 48 Evans, M.C., Parsons, E.M., Scott, R.D., Thornhill, T.S., Zurakowski, D. (2006). Comparative flexion after rotating-platform versus fixed-bearing total knee arthro- plasty. J Arthroplasty, 21 (7): 985-991.
  22. 113 Marrs, H., Barton, D.C., Jones, R.A., Ward, I.M., Fisher, J., Doyle, C. (1999). Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene. J Mater Sci Mater Med, 10 (6): 333-342.
  23. Geiger, F., Mau, H., Krüger, M., Thomsen, M. (2008). Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg, 128 (3): 285-291.
  24. Comparison of anterior-posterior-glide and rotating-platform low contact stress mo- bile-bearing total knee arthroplasties. J Bone Joint Surg Am, 86-A (6): 1239-1247.
  25. Comparison of Computer-Assisted Navigation and Conventional Instrumentation for Bilateral Total Knee Arthroplasty. J Arthroplasty, 24 (5): 668-673.
  26. Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Or- thop Relat Res, (392): 101-115.
  27. Computer-assisted and conventional total knee replacement: a comparative, prospec- tive, randomised study with radiological and CT evaluation. J Bone Joint Surg Br, 90 (8): 1039-1044.
  28. 161 Stiehl, J. B., Konermann, W. H., Haaker, R. G. (2005). Computer-Assisted Surgery: Principles. In: J. Bellemans, M. D. Ries, J. Victor (Hrsg.), Total Knee Arthroplasty -A guide to get better performance.: 241-246. Ber- lin, Heidelberg, New York: Springer-Verlag.
  29. 166 Tingart, M., Lüring, C., Bäthis, H., Beckmann, J., Grifka, J., Perlick, L. (2008). Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc, 16 (1): 44-50.
  30. Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventio- nally implanted prostheses. J Arthroplasty, 20 (7): 832-839.
  31. Contact stress analysis in meniscal bearing total knee arthroplasty. J Arthroplasty, 13 (6): 699-706.
  32. Controlling the motion of total knee replacements using intercondylar guide surfa- ces. J Orthop Res, 18 (1): 48-55.
  33. Conventional and cross-linked polyethylen properties. In: J. Bellemans, M. D. Ries, J. Victor (Hrsg.), Total Knee Arthroplasty -A guide to get better performance.: 353- 360. Berlin, Heidelberg, New York: Springer-Verlag.
  34. Coronal alignment after total knee replacement. J Bone Joint Surg Br, 73 (5): 709- 714.
  35. Design forms of total knee replacement. Proc Inst Mech Eng [H], 214 (1): 101-119.
  36. Differences in patellofemoral contact stresses between mobile-bearing and fixed- bearing total knee arthroplasties: a dynamic in vitro measurement. Arch Orthop Trauma Surg, 129 (7): 901-907.
  37. Dislocation of posterior-stabilized mobile-bearing knee prosthesis. A case report. Knee, 13 (6): 478-482.
  38. Dislocation of the rotating platform after low contact stress total knee arthroplasty. Clin Orthop Relat Res, (425): 207-211.
  39. 176 Wohlrab, D., Ditl, J., Herrschelmann, R., Schietsch, U., Hein, W., Hube, R. (2005). Does the NexGen LPS flex mobile knee prosthesis offer advantages compared to the NexGen LPS? -a comparison of clinical and radiological results. Z Orthop Ihre Grenzgeb, 143 (5): 567-572.
  40. Early postoperative functional differences between total knee arthroplasties supplied with mobile-bearing platform or fixed-bearing system -an analysis of gait pattern. Z Orthop Ihre Grenzgeb, 142 (1): 40-45.
  41. Lampe F., Dries S., Sufi-Siavach A., Hille E., Stulberg D.: Ergebnisse nach Knieen- doprothesen mit fixierter versus rotierender Plattform – eine prospektive, randomisierte Studie. Deutscher Kongress für Orthopädie und Unfallchirurgie (2006), Berlin.
  42. Factors affecting polyethylene wear in total knee arthroplasty. Orthopedics, 25 (2 Suppl): 235-242.
  43. Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene. Biomaterials, 27 (8): 1550-1557.
  44. Fat-pad impingement after total knee arthroplasty with the LCS A/P-Glide system.
  45. Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthro- plasty. J Bone Joint Surg Br, 77 (6): 884-889.
  46. Functional rating for knee arthroplasty: comparison of three scoring systems. Ortho- pedics, 26 (2): 143-149.
  47. History of total knee replacement. J South Orthop Assoc, 11 (4): 218-226.
  48. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc, 16 (3): 249-257.
  49. 51 Fisher, J., McEwen, H.M., Barnett, P.I., Bell, C., Stone, M.H., Ingham, E. (2004). Influences of sterilising techniques on polyethylene wear. Knee, 11 (3): 173-176.
  50. In vitro kinematic patterns are similar for a fixed platform and a mobile bearing prosthesis. J Arthroplasty, 17 (4): 467-474.
  51. Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis? Arthritis Rheum, 55 (2): 306-313.
  52. J-integral fracture toughness and tearing modulus measurement of radiation cross- linked UHMWPE. J Orthop Res, 20 (6): 1152-1156.
  53. 63 Hamai, S., Miura, H., Higaki, H., Shimoto, T., Nakanishi, Y., Iwamoto, Y. (2008). Kinematic analysis of mobile-bearing total knee arthroplasty using a 6-DOF knee simulator. J Orthop Sci, 13 (6): 543-549.
  54. Kinematic comparison between mobile-bearing and fixed-bearing inserts in NexGen legacy posterior stabilized flex total knee arthroplasty. J Arthroplasty, 23 (2): 164- 169.
  55. Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts. J Arthroplasty, 19 (7): 887-897.
  56. Knee stability in meniscal bearing total knee arthroplasty. J Arthroplasty, 14 (1): 82- 90.
  57. Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. Knee, 15 (2): 80-84.
  58. Ligamentous balancing in rotating-platform knees. Orthopedics, 29 (9 Suppl): S56- 59.
  59. Long-term results of low contact stress mobile-bearing total knee replacements. Clin Orthop Relat Res, (416): 265-270.
  60. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proc Inst Mech Eng [H], 210 (3): 141-155.
  61. Knee arthroplasty. Mobile-and fixed-bearing design. Orthopäde, 32 (6): 477-483.
  62. Mobile bearings in primary knee arthroplasty. J Am Acad Orthop Surg, 9 (6): 355- 364.
  63. Mobile-bearing total knee prosthesis: a 5-to 9-year follow-up of the first 110 conse- cutive arthroplasties. J Arthroplasty, 19 (6): 678-685.
  64. Dries S., Sufi-Siavach A., Lemke K., Lampe F., Hille E.: Mobile versus fixed bearing in computer assisted total knee arthroplasty – preliminary results of a randomised study.
  65. Teilveröffentlichungen Teile dieser Arbeit werden/wurden bereits wie folgt publiziert: 10.1. Vorträge und Poster Dries S., Sufi-Siavach A., Lemke K., Lampe F., Hille E.: Mobile versus fixed bearing in cruciate retaining, computer assisted total knee surface replacement – preliminary results of a randomised, double-blind study (Poster). 54. Jahrestagung der Norddeutschen Orthopädenvereinigung (2005), Hamburg.
  66. Mobile-vs. fixed-bearing total knee arthroplasty: a clinical and radiologic study. J Arthroplasty, 19 (2): 135-140.
  67. Modular fixed-bearing total knee arthroplasty with retention of the posterior cruciate ligament. A study of patients followed for a minimum of fifteen years. J Bone Joint Surg Am, 87 (3): 598-603.
  68. Molekulare Grundlagen der Arthroseinduktion und -progression. Orthopäde, 30 (11): 825-833.
  69. Mielke, R.K., Clemens, U., Jens, J.H., Kershally, S. (2001). Navigation in knee endoprosthesis implantation -preliminary experiences and pro- spective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb, 139 (2): 109-116.
  70. Lampe F., Sufi-Siavach A., Hille E., Dries S.: No clinically relevant difference one year after fixed or mobile bearing total knee replacement in a double-blind randomized controlled trial.
  71. Official report of the "Medicines and Healthcare Products Regulatory Agency". De- partment of Health, UK MDA 01025.
  72. Oxford medial unicompartmental knee arthroplasty. A survival analysis of an inde- pendent series. J Bone Joint Surg Br, 83 (2): 191-194.
  73. Patient-reported outcomes after fixed-versus mobile-bearing total knee replacement: a multi-centre randomised controlled trial using the Kinemax total knee replace- ment. J Bone Joint Surg Br, 90 (9): 1172-1179.
  74. Postoperative alignment of total knee replacement. Its effect on survival. Clin Or- thop Relat Res, (299): 153-156.
  75. Dries S., Sufi-Siavach A., Lemke K., Bohlen K., Hille E., Lampe F.: Preliminary results of a prospective randomised study – fixed vs. mobile bearing computer assisted total knee arthroplasty (Poster). 7th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS) (2007), Heidelberg.
  76. Prevalence of Osteolysis After Simultaneous Bilateral Fixed-and Mobile-Bearing Total Knee Arthroplasties in Young Patients. J Arthroplasty, 24 (6): 932-940.
  77. Quality of life: patients and doctors don't always agree: a meta-analysis. J Clin Epi- demiol, 57 (7): 653-661.
  78. 97 Kurtz, S.M., Pruitt, L.A., Jewett, C.W., Foulds, J.R., Edidin, A.A. (1999). Radiation and chemical crosslinking promote strain hardening behavior and mole- cular alignment in ultra high molecular weight polyethylene during multi-axial loa- ding conditions. Biomaterials, 20 (16): 1449-1462.
  79. Radiographic analysis of low contact stress meniscal bearing total knee replace- ments. J Bone Joint Surg Am, 83-A (2): 229-234.
  80. Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg Sports Traumatol Arthrosc, (Epub ahead of print).
  81. Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg, 9 (4): 161-165.
  82. Dezember 1958 in der Fassung vom 22. März 2006 ehrenwörtlich, dass ich die dem Fachbereich Medizin Marburg zur Promotionsprüfung eingereichte Arbeit mit dem Titel " Rotierendes oder fixiertes Tibiainlay? Randomisierter klinischer und radiologischer Vergleich rotierender und fixierter Tibiainlays bei computerassistiertem bikondylärem Kniegelenkoberflächenersatz " in der Abteilung für Orthopädie und Unfallchirurgie der Asklepiosklinik Eilbek, heute nach Betriebsübergang Schön Klinik Hamburg-Eilbek, unter Leitung von Prof. Dr. med. Ekkehard Hille, ohne sonstige Hilfe selbst durchgeführt und bei der Abfassung der Arbeit keine anderen als die in der Dissertation angeführten Hilfsmittel benutzt habe. Ich habe bisher an keinem in-oder ausländischen medizinischen Fachbereich ein Gesuch um Zulassung zur Promotion eingereicht oder die vorliegende oder eine andere Arbeit als Dissertation vorgelegt. Teile der vorliegenden Arbeit wurden in den auf der nächsten Seite genannten Publikationsorganen veröffentlicht. Hamburg, den 10.09.2009
  83. 175 White, S.E., Whiteside, L.A., McCarthy, D.S., Anthony, M., Poggie, R.A. (1994). Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components. Clin Orthop Relat Res, (309): 176-184.
  84. Simultaneous mobile-and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of pros- thesis. J Bone Joint Surg Br, 89 (7): 904-910.
  85. 108 Lüring, C., Hüfner, T., Perlick, L., Bäthis, H., Krettek, C., Grifka, J. (2005). Soft tissue management in knees with varus deformity. Computer-assisted sequential medial ligament release. Orthopäde, 34 (11): 1118-1124.
  86. Staged bilateral mobile-bearing and fixed-bearing total knee arthroplasty in the same patients: a prospective comparison of a posterior-stabilized prosthesis. Knee Surg Sports Traumatol Arthrosc, 17 (3): 237-243.
  87. Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res, (345): 79- 86.
  88. The correction of knee alignment in 225 consecutive total condylar knee replace- ments. Clin Orthop Relat Res, (160): 94-105.
  89. The effect of surgeon experience on component positioning in 673 Press Fit Condy- lar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty, 16 (5): 635-640.
  90. The foundations of computer assisted surgery. Orthopäde, 35 (10): 1032-1037.
  91. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech, 38 (2): 357-365.
  92. The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient. J Bone Joint Surg Br, 89 (10): 1317- 1323.
  93. The need for a dual rating system in total knee arthroplasty. Clin Orthop Relat Res, (345): 161-167.
  94. Theory and practice of meniscal knee replacement: designing against wear. Proc Inst Mech Eng [H], 210 (3): 217-222.
  95. The press-fit condylar modular total knee system with a posterior cruciate-substi- tuting design. A concise follow-up of a previous report. J Bone Joint Surg Am, 88 (5): 1006-1010.
  96. The reliability of navigation-guided gap technique in total knee arthroplasty. Ortho- pedics, 31 (10 Suppl 1).
  97. The reliability of the American Knee Society Score. Acta Orthop Scand, 71 (6): 603-608.
  98. The role of macrophages in osteolysis of total joint replacement. Biomaterials, 26 (11): 1271-1286.
  99. The spectrum of prosthesis design for primary total knee arthroplasty. Instr Course Lect, 52: 397-407.
  100. Three-Dimensional Tibiofemoral Kinematics During Deep Flexion Kneeling in a Mobile-Bearing Total Knee Arthroplasty. J Arthroplasty, (Epub ahead of print).
  101. Tibial malalignment of mobile-bearing prostheses -a simulator study. Orthopäde, 32 (4): 296-304.
  102. Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br, 67 (4): 551-556.
  103. Oxidized Zirkonium. In: J. Bellemans, M. D. Ries, J. Victor (Hrsg.), Total Knee Arthoplasty -A guide to get better performance.: 370-377. Berlin, Heidelberg, New York: Springer-Verlag.
  104. Ries, J. Victor (Hrsg.), Total Knee Arthroplasty -A guide to get better performance.: 361-364. Berlin, Heidelberg, New York: Springer-Verlag.
  105. Total knee arthroplasty. Current clinical perspectives. Clin Orthop Relat Res, (276): 26-32.
  106. Hart, R., Janecek, M., Chaker, A., Bucek, P. (2003). Total knee arthroplasty implanted with and without kinematic navigation. Int Or- thop, 27 (6): 366-369.
  107. Total knee replacement in young, active patients. Long-term follow-up and functio- nal outcome. J Bone Joint Surg Am, 79 (4): 575-582.
  108. Total knee replacement: is it really an effective procedure for all? Knee, 14 (6): 417- 423.
  109. Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR. Knee Surg Sports Traumatol Arthrosc, 14 (7): 605-611.
  110. Ultra-high molecular weight polyethylene. The material and its use in total joint implants. J Bone Joint Surg Am, 76 (7): 1080-1090.
  111. Uncemented rotating-platform total knee replacement: a five to twelve-year follow- up study. J Bone Joint Surg Am, 86-A (10): 2156-2162.
  112. Koshino, T., Takeyama, M., Jiang, L.S., Yoshida, T., Saito, T. (2002). Underestimation of varus angulation in knees with flexion deformity. Knee, 9 (4): 275-279.
  113. Unified wear model for highly crosslinked ultra-high molecular weight polyethy- lenes (UHMWPE). Biomaterials, 20 (16): 1463-1470.
  114. 103 Lingard, E.A., Katz, J.N., Wright, R.J., Wright, E.A., Sledge, C.B. (2001). Validity and responsiveness of the Knee Society Clinical Rating System in compa- rison with the SF-36 and WOMAC. J Bone Joint Surg Am, 83-A (12): 1856-1864.
  115. Value of navigation and robot-guided surgery in total knee arthroplasty. Orthopäde, 32 (6): 498-505.
  116. Wear in conventional an highly cross-linked polyethylen. In: J. Bellemans, M. D.
  117. Wear-simulation analysis of rotating-platform mobile-bearing knees. Orthopedics, 29 (9 Suppl): S36-41.
  118. Wear testing of materials and surfaces for total knee replacement. J Biomed Mater Res, 33 (3): 159-175.
  119. Mobile vs. fixed meniscal bearing in total knee replacement: a randomised radio- stereometric study. Knee, 12 (6): 414-418.
  120. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res, (248): 13-14.
  121. Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop Relat Res, (432): 204-209.
  122. Patients' versus general practitioners' assessments of pain intensity in primary care patients with non-cancer pain. Br J Gen Pract, 51 (473): 995-997.
  123. Rotating platform versus fixed-bearing total knees: an in vitro study of wear. Clin Orthop Relat Res, 466 (11): 2677-2685.
  124. 150 Seon, J.K., Park, S.J., Lee, K.B., Li, G., Kozanek, M., Song, E.K. (2009). Functional comparison of total knee arthroplasty performed with and without a navi- gation system. Int Orthop, 33 (4): 987-990.
  125. Follow-up of 11-16 years after modular fixed-bearing TKA. Int Orthop, 33 (2): 431- 435.
  126. Macule-Beneyto, F., Hernandez-Vaquero, D., Segur-Vilalta, J.M., Colomina- Rodriguez, R., Hinarejos-Gomez, P., Garcia-Forcada, I., Seral Garcia, B. (2006). Navigation in total knee arthroplasty. A multicenter study. Int Orthop, 30 (6): 536- 540.


* Das Dokument ist im Internet frei zugänglich - Hinweise zu den Nutzungsrechten